CDWZN - HYDROGEN, MGI11120
- MSDS: CDWZN
- Manufacturer: MG INDUSTRIES
- Product Name: HYDROGEN, MGI11120
- National Stock Number: 6830-00-180-5919
Product Identification
Product ID:HYDROGEN, MGI11120
MSDS Date:03/24/1993
FSC:6830
NIIN:00-180-5919
MSDS Number: CDWZN
Responsible Party
VALLEY FORGE, PA 19482
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 215-695-7400
Cage: 08772
Contractor
Telephone: 610-695-7400 / 610-695-7449
Cage: 08772
Ingredients
HYDROGEN
CAS: 1333-74-0
RTECS: MW8900000
Fraction By Weight: 100%
OSHA PEL N/K
ACGIH TLV: N/K
UNMANNED HOLDER/MONITOR NOZZ; IF THIS IS IMPOSS,
RTECS: 9999999ZZ
RISING SOUND FORM VENTING SFTY DEVICE/ANY
RTECS: 9999999ZZ
BURN UNLESS LEAK CAN BE STOPPED; W/SMALLER
RTECS: 9999999ZZ
MILE IN ALL DIRECTIONS IF TANK, RAIL CAR/TANK TRUCK
RTECS: 9999999ZZ
STOPPED. USE FLOODING AMTS OF WATER AS FOG. COOL CYLS
RTECS: 9999999ZZ
AVOID BRTHG VAPS; KEEP UPWIND. IF FIRE IS
RTECS: 9999999ZZ
1500 FEET. CONSIDER EVACUATION OF DOWNWIND AREA IF
RTECS: 9999999ZZ
TO RAPID EVAP, LIQ MAY CAUSE FROSTBITE
RTECS: 9999999ZZ
UNLIKELY. IF LIQ IS SWALLOWED, FROSTBITE DMG TO LIPS,
RTECS: 9999999ZZ
SIMPLE ASPHYXIANT.
RTECS: 9999999ZZ
107F. IF WARM WATER IS NOT AVAIL/IMPRACTICAL
RTECS: 9999999ZZ
ENCOURAGE VICTIM TO EXERCISE AFFECTED PART WHILE IT
RTECS: 9999999ZZ
IF CONT
RTECS: 9999999ZZ
EVID OF CHEM REMAINS (AT LST 15-20 MINS). GET MED
RTECS: 9999999ZZ
SYMPTOMATICALLY & SUPPORTIVELY & GET MEDICAL
RTECS: 9999999ZZ
CNTNRS WHICH MEET BONDING & GROUNDING GUIDELINES
RTECS: 9999999ZZ
ELEC. VAPS MAY BE EXPLO. DO NOT ALLOW CONT W/SKIN;
RTECS: 9999999ZZ
MAY RUPTURE VIOLENTLY & TRAVEL A CONSIDERABLE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:SIMPLE ASPHY. SYMPS OF
ASPHYXIA DEPEND ON RAPIDITY W/WHICH OXYG DEFICIENCY DEVELOPS & HOW
LONG IT CONTINUES. IN SUDDEN ACUTE ASPHYXIA, UNCON MAY BE IMMED,
W/SLOW DEVEL. THERE MAY BE RAPID RESP & PULSE, AIR HUNGER, DIZZ,
REDUCEDAWARENESS, TIGHTNESS IN HEAD, TINGLING SENSATIONS, INCOORD,
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:FAULTY JUDGEMENT, EMOTIONAL
INSTABILITY & RAPID FATG. AS ASPHYXIA PROGRESSES, NAUS, VOMIT,
COLLAPSE, UNCON, CONVLS, DEEP COMA & DEATH ARE POSS. SKIN:DUE TO
RAPID EVAP, LIQ MAY CAUSE FROSTBITE W/REDNESS, TINGLING &
PAIN/NUMB. IN MORE SEV CASES, SKIN MAY BECOME HARD & WHITE &
DEVELOP BLISTERS. EYE:DUE (ING 9)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE FROM EXPOS AREA TO FRESH AIR IMMED. IF BRTHG HAS
STOPPED, GIVE ARTF RESP. MAINTAIN AIRWAY & BLOOD PRESS & ADMIN OXYG
IF AVAIL. KEEP AFFECTED PERS WARM & AT REST. TREAT SYMPTOMATICALLY
& S UPPORTIVELY. ADMIN OF OXYG SHOULD BE PERFORMED BY QUALIFIED
PERS. GET MED ATTN. SKIN:IF ADVERSE EFTS OCCUR, GET MED ATTN. IN
CASE OF FROSTBITE, WARM AFFECTED SKIN IN WARM WATER AT TEMP OF (ING
12)
Fire Fighting
Lower Limits:4%
Upper Limits:75%
Extinguishing Media:DRY CHEMICAL OR CARBON DIOXIDE. FOR LARGER FIRES,
USE WATER SPRAY OR FOG.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . MOVE
CNTNRS FROM FIRE AREA IF YOU CAN DO IT W/OUT RISK. APPLY COOLING
WATER TO SIDES OF CNTNRS THAT ARE (SUPDAT)
Unusual Fire/Explosion Hazard:DANGEROUS EXPLO HAZ WHEN EXPOS TO
HEAT/FLAME. VAP-AIR MIXTS ARE EXPLO. CYL MAY EXPLODE IN HEAT OF
FIRE. DUE TO LOW ELECTROCONDUCTIVITY OF SUBSTANCE, (SUPP DATA)
Accidental Release
Spill Release Procedures:SHUT OFF IGNIT SOURCES. DO NOT TOUCH SPILLED
MATL. STOP LEAK IF YOU CAN DO IT W/OUT RISK. USE WATER SPRAY TO
REDUCE VAPS, ISOLATE AREA UNTIL GAS HAS DISPERSED. NO SMOKING,
FLAMES/FLARES IN HAZ AREA! K EEP UNNEC PEOPLE AWAY. ISOLATE HAZ
AREA& (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE ALL FED, STATE & LOC REGS WHEN
STORING THIS SUBSTANCE. STORE I/A/W 29 CFR 1910.103. STORE AWAY
FROM INCOMPATIBLE SUBSTANCES. FLAMMABLE GAS.
Other Precautions:STORE IN COOL, DRY, WELL-VENTED LOCATION.
OUTSIDE/DETACHED STOR IS PREF. ISOLATE FROM OXYG, HALOGENS, OTHER
OXIDIZING MATLS. SUBSTANCES W/LOW ELECTROCONDUCTIVITY, WHICH MAY BE
IGNITED BY ELECTROSTATIC SPKS, SHOULD BE STORED IN (ING 17)
Exposure Controls
Respiratory Protection:SPECIFIC RESP SELECTED MUST BE BASED ON CONTAM
LEVELS FOUND IN WORK PLACE, SPECIFIC OPERATION, MUST NOT EXCEED
WORKING LIMS OF RESP & BE NIOSH APPRVD: ANY SUPPLIED-AIR RESP
OPERATED IN PRESS-DEMAND/OT HER POS PRESS MODE; ANY SCBA.
Ventilation:PROVIDE LOCAL EXHAUST OR GENERAL DILUTION VENTILATION.
VENTILATION EQUIPMENT MUST BE EXPLOSION-PROOF.
Protective Gloves:COLD INSULATING GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS &(SUPDAT)
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER . WEAR APPROP PROT CLOTHING & EQUIP TO PREVENT SKIN FROM
FREEZING.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN.
Supplemental Safety and Health
EXPLO HAZ:FLOW/AGITATION. MAY GENERATE ELECTROSTATIC CHARGES RSLTG IN
SPKS W/POSS IGNIT. SPILL PROC:DENY ENTRY. VENT CLSD SPACES BEFORE
ENTERING. EYE PROT:FULL LGTH FSHLD . FIRE FIGHT PROC:EXPOS TO
FLAMES UNTIL WELL AFTER FIRE IS OUT. STAY AWAY FROM ENDS OF TANKS.
FOR MASSIVE FIRE IN CARGO AREA, USE (ING 2)
Chemical Properties
Boiling Pt:B.P. Text:-423F,-253C
Melt/Freeze Pt:M.P/F.P Text:-434F,-259C
Vapor Pres:760 @-253C
Vapor Density:0.07
Spec Gravity:0.08987
Solubility in Water:1.82% @ 20C.
Appearance and Odor:COLORLESS, TASTELESS GAS; ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
ALKALINE METALS, LIQ NITROGEN & ALKENES, NITROGEN OXIDE, OXIDIZERS. FOR
COMPLETE LIST OF MATLS TO AVOID CONT NEHC.
Stability Condition to Avoid:AVOID CONTACT W/HEAT, SPARKS, FLAMES OR
OTHER IGNITION SOURCES.
Hazardous Decomposition Products:NONE HAZARDOUS.
Disposal
Waste Disposal Methods:OBSERVE ALL FEDERAL, STATE & LOCAL REGULATIONS
WHEN DISPOSING OF THIS SUBSTANCE. DISPOSAL MUST BE I/A/W STDS
APPLIC TO GENERATORS OF HAZARDOUS WASTE, 40 CFR 262. EPA HAZARDOUS
WASTE NUMBER D001. CERCL A REPORTABLE QUANTITY:100 LBS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.